1. Product overview
The DC charger is in compliance with IEC 61851-1:2017, EN 61851-1:2010, EN 61851-23:2014, EN 61851-24:2014, IEC 61851-21-2:2018, GB/T18487.1-2015, and the corresponding communication standards GB/T 27930-2015, GB/T 34657.1-2017, GB/T 34658-2017. The communication protocol with central management system (CMS) is in compliance with OCPP 1.6 based on ARM architecture and Linux / Android platform.
Nomenclature: 3P15K-D1-20A-AS01
3P | 3 phase input |
15K | Rated output power |
D1 | DC output with two charging connector |
20A | Rated current of charging connector |
AS01 | version 01 |
2. Announcements
- Install, maintain and repair the DC charger under power OFF.
- Non-professionals are forbidden to open the door when the power is on.
- Don’t try to remove the connector during charging.
- Press the emergency stop button when abnormal operation.
- Do not stack sundries at the bottom and back of the charger to block the ventilation.
- Dedust the inside every month, especially for the strainer.
- Check the SPD every month, which is in the back of the charger. Replace the SPD when the indicator is in red.
- Technical parameters
Item Number | 3P15K-D1-20A-AS01 | |
Power input | Input rating | AC220V 2ph Wye 100A max. |
Number of phase / wire | 2ph / L1,L2, PE | |
Power factor | >0.98 | |
Current THD | <5% | |
Efficiency | >95% | |
Power output | Output power | 15kW (2gun) |
Output rating | DC200V-750V DC | |
Output accuracy | <0.5% (voltage and current) | |
Protection | Protection | Over current, Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault |
User interface & control | Display | 7” touch screen |
Support language | English (Other languages available upon request) | |
Charge option | Charge options to be provided upon request: Charge by duration, Charge by energy, Charge by fee | |
Environmental | Operating temperature | minus 20 ℃to+55℃ (derating when over 55℃) |
Storage temperature | -40 ℃to+70℃ | |
Humidity | < 95% relative humidity, non-condensing | |
Altitude | Up to 2000 m (6000 feet) | |
Mechanical | Ingress protection | IP54 |
Enclosure Protection against External Mechanical Impacts | IK10 according to IEC 62262 | |
Cooling | Air forced | |
Charging cable length | 5m | |
Dimension (W*D*H) mm | 700*780*1720mm | |
Weight | 40kg |
- Service environment
- Operation temperature: -20⁰C…+55⁰C
- RH: 5%…95%
- Attitude: <2000m
- Installation environment: without strong magnetic interference.
- Peripheral space: >0.1m
- Installation
V.1 installation condition
- The charger should be installed on a flat concrete foundation, with a cable entrance reserved.
- The vertical inclination is less than 5%.
- Fix the bottom of the charger by eight M8 screws embedded in the foundation.
- Keep at least 100cm spacing around the charger for heat dissipation and operation
- An Awning is recommended.
6. Preparing for use
- Insure the input circuit breaker in clause 5.2 is OFF.
- Check the earthing is correct and the input voltage is correct.
- Close the circuit breaker in clause 5.2 to ON.
- Check the door is locked correct.
- Press the ON button and access into service.