15Kw operation MANUAL- DC wallbox

1. Product overview

The DC charger is in compliance with IEC 61851-1:2017, EN 61851-1:2010, EN 61851-23:2014, EN 61851-24:2014, IEC 61851-21-2:2018, GB/T18487.1-2015, and the corresponding communication standards GB/T 27930-2015, GB/T 34657.1-2017, GB/T 34658-2017. The communication protocol with central management system (CMS) is in compliance with OCPP 1.6 based on ARM architecture and Linux / Android platform.

Nomenclature: 3P15K-D1-20A-AS01           

3P3 phase input
15KRated output power
D1DC output with two charging connector
20ARated current of charging connector
AS01version 01

2. Announcements

  1. Install, maintain and repair the DC charger under power OFF.
  2. Non-professionals are forbidden to open the door when the power is on.
  3. Don’t try to remove the connector during charging.
  4. Press the emergency stop button when abnormal operation.
  5. Do not stack sundries at the bottom and back of the charger to block the ventilation.
  6. Dedust the inside every month, especially for the strainer.
  7. Check the SPD every month, which is in the back of the charger. Replace the SPD when the indicator is in red.
  1. Technical parameters
Item Number3P15K-D1-20A-AS01
Power  inputInput ratingAC220V 2ph Wye 100A max.
Number of phase / wire2ph / L1,L2, PE
Power factor>0.98
Current THD<5%
Efficiency >95%
Power  outputOutput power15kW (2gun)
Output ratingDC200V-750V DC
Output accuracy<0.5% (voltage and current)
ProtectionProtection Over current, Under voltage, Over voltage, Residual current, Surge protection, Short circuit, Over temperature, Ground fault
User interface & controlDisplay 7” touch screen
Support languageEnglish (Other languages available upon request)
Charge optionCharge options to be provided upon request: Charge by duration, Charge by energy, Charge by fee
Environmental Operating temperatureminus 20 ℃to+55℃ (derating when over 55℃)
Storage temperature-40 ℃to+70℃
Humidity < 95% relative humidity, non-condensing
Altitude Up to 2000 m (6000 feet)
Mechanical Ingress protectionIP54
Enclosure Protection against  External Mechanical ImpactsIK10 according to IEC 62262
Cooling Air forced
Charging cable length5m
Dimension (W*D*H) mm700*780*1720mm 
Weight40kg
  1. Service environment
    1. Operation temperature: -20⁰C…+55⁰C
    2. RH: 5%…95%
    3. Attitude: <2000m
    4. Installation environment: without strong magnetic interference.
    5. Peripheral space: >0.1m
  1. Installation

V.1 installation condition

  1. The charger should be installed on a flat concrete foundation, with a cable entrance reserved.
  2. The vertical inclination is less than 5%.
  3. Fix the bottom of the charger by eight M8 screws embedded in the foundation.
  4. Keep at least 100cm spacing around the charger for heat dissipation and operation
  5. An Awning is recommended.

6. Preparing for use

  1. Insure the input circuit breaker in clause 5.2 is OFF.
  2. Check the earthing is correct and the input voltage is correct.
  3. Close the circuit breaker in clause 5.2 to ON.
  4. Check the door is locked correct.
  5. Press the ON button and access into service.